 Search 
   
The floating-point unit of a S/390 CMOS microprocessor is described. It contains a 116 bit fraction dataflow for addition and subtraction and a 64 bit-wide multiplier. Besides the register array, there are no other dataflow macros used; it is fully designed with standard cell books and is placed flat with a timing driven placement algorithm. This design method allows more 'irregular' structures than usually found in custom designs.An overview of the floating-point unit is given and some interesting design items are shown: a 120 bit-wide true-complement adder with precounting of leading zero digits, a signed multiplier with bit-optimized Wallace tree, intensive forwarding in source equal target cases and the checking method.
Citation:
Guenter Gerwig, Michael Kroener, "Floating-Point Unit in Standard Cell Design with 116 Bit Wide Dataflow," arith, pp.266, 14th IEEE Symposium on Computer Arithmetic (ARITH-14 '99), 1999